Temporary Electricity Safety Common Sense
Temporary electricity refers to the design, installation, use, maintenance and removal of low-voltage power systems using electric equipment and lighting on the production and construction sites during temporary overhaul or maintenance and engineering construction. The main facilities and materials for temporary power utilization include transformers, power distribution cabinets, distribution boxes, switch boxes, cables, wires, electrical tools, electric tools, lighting fixtures, electrical equipment, etc. Basic management requirements for
temporary power consumption:
1.
temporary power consumption organization design shall be prepared for the construction site with 5or more temporary power consumption equipment or the total capacity of equipment is 50kW or more. 2.
Temporary electricity consumption organization design must follow the "preparation, review and approval " procedure, which shall be organized and compiled by electrical engineering technicians and implemented after being reviewed by relevant departments and approved by the technical director of the enterprise with legal personality. 3.
Temporary power consumption project shall be constructed according to the design drawing, and shall be jointly accepted by relevant units before being put into use after being qualified.4.
Temporary electricity use must establish safety technical files, which shall be established and managed by electrical technicians. Among them, "electrician installation, inspection, maintenance and demolition work record " can be assigned to be managed by an electrician, which shall be reviewed and approved by the main person in charge or project manager every week, and shall be filed uniformly after the temporary power consumption project is demolished. 5.
Temporary power consumption shall be checked regularly, potential safety hazards shall be handled in time, and rechecked and accepted.Basic requirements for electricians and electricity users:
1.
Electricians must pass the examination and obtain the special operation certificate before taking up their posts; Other electricity users must undergo safety training and technical disclosure before they can take up their posts.2.
Installation, inspection, maintenance or removal of temporary electrical equipment and lines must be completed by an electrician and supervised by a special person.All kinds of electricity users should master the basic knowledge of safe electricity use and the performance of the equipment used, and should meet the following regulations:
1.
Before using electrical equipment, they must wear and equip corresponding labor protection articles according to regulations, and check electrical devices and protection facilities. It is strictly forbidden for equipment to operate with diseases.2.
Keep and maintain the equipment used, report and solve any problems found in time;3.
The switch box of temporarily deactivated equipment must disconnect the power isolation switch and close the door and lock it.4.
When moving electrical equipment, the power supply must be cut off by an electrician and properly handled. Introduction toElectrical Equipment:
1.
Electrical Equipment Switches shall adopt automatic control electrical appliances such as contactors and relays, and manual two-way transfer switches shall not be used as control electrical appliances.2. In the switch box of Class I
and Class IImetal shell hand-held electric tools, the rated leakage action current of the leakage protector shall not be greater than 15mA , and the rated leakage action time shall not be greater than 0.1s . 3.
When operating in wet places and on metal frames, Class IIor Class III hand-held power tools powered by safety isolation transformers must be selected. 4.
It is strictly forbidden to use Class Ihand-held electric tools in wet places or on metal frames. 5.
The load line of the water pump must adopt waterproof rubber sheathed copper core flexible cable. Any damage and joints are strictly prohibited, and no external force is allowed.When cleaning, inspecting and maintaining concrete mixers, steel bar processing machinery, woodworking machinery and other equipment, the switch box must first be switched off and powered off, showing visible power breaking points, and the door must be closed and locked.
hang the sign of no closing and be monitored by special personnel. (Liu Fengbin)
More information
The company organized "charity one day donation"
On the morning of October 22, in the lobby on the first floor of Jianfeng Building, all cadres and employees of the group headquarters and subordinate enterprises working in Jianfeng Building participated in the 2021 "Charity Day Donation" activity to offer their love to Jinhua charity. In the next few days, the company's subordinate enterprises also organized "charity one-day donation" activities one after another.
2021
11-01
The company organizes new employee induction training
"Growth is more important than success. I hope everyone can become the backbone and pillars of the peak as soon as possible." On September 2, Yu Jianhong, general manager of the group company, put forward ardent hopes in the face of new employees. On the 2nd and 3rd, the group company organized induction training for new employees recruited in the past year. The group company chairman Jiang Xiaomeng, general manager Yu Jianhong and other leaders and relevant department heads gave lectures to them.
2021
09-13
Daye Peak: Typical Regional Industrial Green Development
On August 23, Huangshi Radio and Television Station broadcast the special program of "Strengthening Overall Planning and Promoting Energy Saving and Emission Reduction in Industrial Field". Daye Jianfeng Cement Company, as a typical enterprise with outstanding achievements in establishing green factories and energy saving and emission reduction in Huangshi area, appeared in the program.
2021
09-01
Yunnan Peak Helps Border Epidemic Prevention and Control
On August 22, Yunnan Peak Cement Company, through the Red Cross Society of Pu'er City and the Epidemic Prevention Headquarters of Pu'er City, donated vacuum insulation pots with a total value of 800000 yuan to the four border counties for the prevention and control of the new coronary pneumonia epidemic in the border area, and supported the prevention and control of the epidemic at the border with practical actions.
2021
09-01
Group Party Committee to Learn "July 1" Important Speech
On August 13, the party committee of the group company held a special meeting to collectively study General Secretary Xi Jinping's important speech at the celebration meeting of the 100 anniversary of the founding of the Communist Party of China, convey the requirements of the party committee at a higher level, and make arrangements for organizing party members of the company to study the "July 1" speech.
2021
08-23
Spike Ranked 2020 China's Top 100 Cement Clinker Production Capacity
Recently, the company received the "2020 China Cement Clinker Production Capacity Top 100" plaque issued by China Cement Network. The ranking of China's top 100 cement clinker production capacity is organized and evaluated by China Cement Network, an authoritative information platform for the domestic cement industry. It is released according to the actual clinker production capacity of each cement enterprise at the end of last year. The company has been ranked in the top 100 list for many consecutive years.
2021
08-23